top of page

Square D 2000 amp outdoor non-walkin QED I line switchboard 

Square D main lugs only, 2000 amp, QED outdoor non-walkin I line switchboard

This unit is in very like new condition. It was installed in the Fall of 2020 and used for two weeks. It has knockouts for the existing feeders and can easily be re-installed at your facility.

It is located in storage in Dallas TX. We can arrange shipping for you or we would be happy to load it on your truck.

We have all the original approval submittals and their are like new electronic trip I line breakers available. They are not included in this offering.

With the factory being overloaded, you can get Square D quality equipment at a good price and quick delivery.

Questions

Make an offer

I need I line breakers

2000A SQD switchgear 01.jpg

Designation : TEMP MDP

 

1-Square D Standard Switchboard Series 2-QED-2 Switchboard

Square D Standard Switchboard Series 2 Designed and Tested in accordance with: UL 891/NATIONAL ELECTRIC CODE/NEMA PB-2

System Voltage - 480Y/277V 3Ph 4W 60Hz

Source Description - Main is Remote System Ampacity - 2000A Bussing - Silver Plated Copper Neutral Bus - 100% Max Available Fault Current (RMS) - 65kA Enclosure –

Type 3R Non-Walk-in Accessibility: Front Only Equipment Nameplate White Surface/Black Letters, Adhesive (Field Installed) Rodent Barrier

Exterior Paint Color - ANSI 49 Ground Lug provided for each device Copper Ground Bus

 

Dimensions 1 - 24" Wide Section(s) 1 - 48" Wide Section(s) 1 - Dimensions: 72.00" W X 35.5" D X 91.5"H 2 - 35.5" Deep Enclosure(s)

Approximate Weight: 1811.00 lbs / 821.47 kgs Incoming Requirements  

UL Dead Front Entry Point: Left of Lineup, Through the Top Connection Type: Cable in Bussed Auxiliary Feeders

 

Devices Associated with Remote Main:

3 - 400AS/350AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type LJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

1 - 400AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Prepared Space: Type LJ

 

2 - 600AS/450AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type LJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

 5 - 100AS/60AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type HJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

1 - 100AS/100AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type HJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

3 - 250AS/175AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type JJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

1 - 225AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Prepared Space: Type JJ 1 - 250AS/200AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type JJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

1 - 150AS/125AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type HJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

 

1 - 100AS/90AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type HJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

1 - 60AS/30AT 480V 80% Rated 65 kA 3 Pole UL, Group Mounted Electronic Trip Circuit Breaker: Type HJ Ammeter Trip Unit, Long Time, Short Time, Instantaneous, Ground Fault

Call or text Tom 414-698-9745

Email milwakeesurplus@yahoo.com

I line circuit breakers